Location: Products > Fluorescence > Lifetime > Dedicated TCSPC Spectrofluorimeter

FluoroCube: Compact lifetime spectrofluometer systems

FluoroCube

Picoseconds to seconds: a compact fluorescence system optimized for use in the time-domain

The FluoroCube combines the latest miniaturized light source and detector technology with proven TCSPC electronics and automation to offer the most flexible and user-friendly photon counting lifetime system available today.

Choose from the most comprehensive range of pulsed light source and detector options, including:

  • Picosecond laser diodes from 370 nm to NIR
  • Nanosecond LEDs from 260 nm to NIR
  • The original nanosecond flashlamp; now in its 4th generation
  • Sub-microsecond xenon flashlamp and LEDs for phosphorescence
  • Ti-sapphire laser and multi-photon options
  • Highly integrated picosecond PMT modules
  • Microchannel plate PMTs for the ultimate in time resolution
  • UV to 1700 nm spectral coverage

Benefit from our 30 years experience in TCSPC by asking your HORIBA Jobin Yvon representative to tailor the perfect lifetime system for your research.

Back to Table

FluoroCube NL
Entry level lifetime system with filter-based optics and diode excitation

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • Excitation optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*: a wide choice of interchangeable laser diode and LED-based excitation sources are available as accessories
  • Emission optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • NanoLED pulsed diode controller module (software controlled)**
  • TBX-04 (185 - 650 nm) picosecond photon-detection module (interlocked with lid of sample compartment)
  • FluoroHub timing electronics - measures picoseconds to seconds (depending on excitation source)
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials) + DAS6-8 Anisotropy
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
*Filters and polarisers are optional
**NanoLED sources must be ordered separately
***System Installation is not included***

 

Back to Table
Back to Table

FluoroCube-01-NL
Lifetime system with emission monochromator and diode excitation

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • Motorized excitation optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*: a wide choice of interchangeable laser diode and LED-based excitation sources are available as accessories
  • Motorized emission optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • Emission monochromator: Seya-Namioka type, featuring motorized wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • NanoLED pulsed diode controller module (software controlled)**
  • TBX-04 (185 - 650 nm) picosecond photon-detection module
  • FluoroHub timing electronics - measures picoseconds to seconds (depending on excitation source)
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials) + DAS6-8 Anisotropy
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 37 x 70 cm baseplate
*Filters and polarizers are optional
**NanoLED sources must be ordered separately
***System Installation is not included***

 

Back to Table
Back to Table

FluoroCube-11-NL
Lifetime system with two monochromators and diode excitation

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • x-y-z sample positioning stage
  • Excitation monochromator
  • Emission monochromator
  • Both monochromators are Seya-Namioka type, featuring motorized wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • Monochromator optics features vertical dispersion for enhanced sensitivity
  • Both optical channels feature motorized optics for computer-optimized focusing, 50 mm UV-grade fused silica lenses, filter holders for 50 mm square filters and mounts for polarizers*
  • NanoLED pulsed diode controller module (software controlled)**
  • TBX-04 (185 - 650 nm) picosecond photon-detection module
  • FluoroHub timing electronics - measures picoseconds to seconds (depending on excitation source)
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials) + DAS6-8 Anisotropy
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 70 x 70 cm baseplate
*Filters and polarizers are optional
**NanoLED sources must be ordered separately
***System Installation is not included***

 

Back to Table
Back to Table

FluoroCube-10-CF
Lifetime system with excitation monochromator (filter detection channel) and flashlamp excitation

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • Excitation monochromator: Seya-Namioka type, featuring motorized wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • Motorized excitation optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • Motorised emission optics with 50mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • Four-position beam steering mirror on excitation monochromator allows multiple excitation sources to be simultaneously mounted at entrance port
  • FluoroSource CF nanosecond coaxial flashlamp**
  • TBX-04 (185 - 650 nm) picosecond photon-detection module
  • FluoroHub timing electronics - measures picoseconds to seconds (depending on excitation source)
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials) + DAS6-8 Anisotropy
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 37 x 70 cm baseplate
*Filters and polarizers are optional
** Includes gas handling system and pump
***System Installation is not included***

 

Back to Table
Back to Table

FluoroCube-11-CF
Lifetime system with two monochromators and flashlamp excitation (formerly the 5000U)

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • x-y-z sample positioning stage
  • Excitation monochromator
  • Emission monochromator
  • Both monochromators are Seya-Namioka type, featuring motorized wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • Monochromator optics features vertical dispersion for enhanced sensitivity
  • Both optical channels feature motorized optics for computer-optimized focusing, 50 mm UV-grade fused silica lenses, filter holders for 50 mm square filters and mounts for polarizers*
  • Four-position beam steering mirror on excitation monochromator allows multiple excitation sources to be simultaneously mounted at entrance port
  • FluoroSource CF nanosecond coaxial flashlamp**
  • TBX-04 (185 - 650 nm) picosecond photon-detection module
  • FluoroHub timing electronics - measures picoseconds to seconds (depending on excitation source)
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials) + DAS6-8 Anisotropy
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 70 x 70 cm baseplate
*Filters and polarizers are optional
** Includes gas handling system and pump
***System Installation is not included***

 

Back to Table
Back to Table

PhosphoCube-10-XF
Phosphorescence lifetime system with excitation monochromator (filter detection channel) and microsecond xenon flashlamp excitation

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • Excitation monochromator: Seya-Namioka type, featuring motorized wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • Motorized excitation optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • Motorized emission optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • Four-position beam steering mirror on excitation monochromator allows multiple excitation sources to be simultaneously mounted at entrance port
  • FluoroSource XF microsecond xenon flashlamp
  • TBX-04 (185 - 650 nm) picosecond photon-detection module
  • FluoroHub timing electronics - phosphorescence measurements only
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials)
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 37 x 70 cm baseplate
*Filters and polarizers are optional
***System Installation is not included***

 

Back to Table
Back to Table

PhosphoCube-11-XF
Phosphorescence lifetime system with two monochromators and microsecond xenon flashlamp excitation

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • x-y-z sample positioning stage
  • Excitation monochromator
  • Emission monochromator
  • Both monochromators are Seya-Namioka type, featuring motorized wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • Monochromator optics features vertical dispersion for enhanced sensitivity
  • Both optical channels feature motorized optics for computer-optimized focusing, 50 mm UV-grade fused silica lenses, filter holders for 50 mm square filters and mounts for polarizers*
  • Four-position beam steering mirror on excitation monochromator allows multiple excitation sources to be simultaneously mounted at entrance port
  • FluoroSource XF microsecond xenon flashlamp
  • TBX-04 (185 - 650 nm) picosecond photon-detection module
  • FluoroHub timing electronics - phosphorescence measurements only
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials)
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 70 x 70 cm baseplate
*Filters and polarizers are optional
***System Installation is not included***

 

Back to Table
Back to Table

PhosphoCube SL
Entry level phosphorescence lifetime system with filter-based optics and diode excitation

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • Excitation optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • Emission optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • SpectraLED microsecond pulsed diode controller module (software controlled)**
  • TBX-04 (185 - 650 nm) picosecond photon-detection module (interlocked with lid of sample compartment)
  • Timing electronics for phosphorescence measurements only
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials)
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
*Filters and polarizers are optional
**SpectraLED sources must be ordered separately
***System Installation is not included***

 

Back to Table
Back to Table

PhosphoCube-01-SL
Phosphorescence lifetime system with emission monochromator and diode excitation

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • Motorized excitation optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • Motorized emission optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • Emission monochromator: Seya-Namioka type, featuring motorized wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • SpectraLED microsecond pulsed diode controller module (software controlled)**
  • TBX-04 (185 - 650 nm) picosecond photon-detection module
  • FluoroHub timing electronics - phosphorescence measurements only
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials)
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 37 x 70 cm baseplate
*Filters and polarizers are optional
**SpectraLED sources must be ordered separately
***System Installation is not included***

 

Back to Table
Click on the product for more detailed information
Wavelength
Selection
Filters
Emission Filter -
Excitation Monochromator
Excitation Filter -
Emission Monochromator
Excitation/Emission
Monochromator
SpectraLED
Light Sources
PhosphoCube-SL PhosphoCube-01-SL
Xenon
Flashlamp
PhosphoCube-10-XF PhosphoCube-11-XF
NanoLED FluoroCube NL FluoroCube-01-NL
UltraFast-01-NL
FluoroCube-11-NL
UltraFast-11-NL
Nano
FlashLamp
FluoroCube-10-CF FluoroCube-11-CF
Ti Laser UltraFast-01-Ti

 

Back to Table

UltraFast-01-NL
Lifetime system with MCP-PMT detection, emission monochromator and NanoLED diode excitation

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • Motorized emission optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • Emission monochromator: Seya-Namioka type, featuring motorized wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • NanoLED pulsed diode controller module (software controlled)**
  • R3809 MCP-PMT detector in cooled housing with close-coupled picotiming amplifier/discriminator
  • Fluoro3PS ultra-stable HV detector power supply
  • FluoroHub timing electronics with FluoroHub-TE option for 0.7 ps/point resolution
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials) + DAS6-8 Anisotropy
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 37 x 70 cm baseplate
*Filters and polarizers are optional
**NanoLED sources must be ordered separately. Laser NanoLED sources recommended for use with MCP detection.
***System Installation is not included***

 

Back to Table
Back to Table

UltraFast-11-NL
Lifetime system with MCP-PMT detection, two monochromators and NanoLED diode excitation

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • x-y-z sample positioning stage
  • Excitation monochromator
  • Emission monochromator
  • Both monochromators are Seya-Namioka type, featuring motorised wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • Both optical channels feature motorized optics for computer-optimized focusing, 50 mm UV-grade fused silica lenses, filter holders for 50 mm square filters and mounts for polarizers*
  • NanoLED pulsed diode controller module (software controlled)**
  • R3809 MCP-PMT detector in cooled housing with close-coupled picotiming amplifier/discriminator
  • Fluoro3PS ultra-stable HV detector power supply
  • FluoroHub timing electronics with FluoroHub-TE option for 0.7 ps/point resolution
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials) + DAS6-8 Anisotropy
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 70 x 70 cm baseplate
*Filters and polarizers are optional
**NanoLED sources must be ordered separately. Laser NanoLED sources recommended for use with MCP detection.
***System Installation is not included***

 

Back to Table
Back to Table

UltraFast-01-Ti
Lifetime system with MCP-PMT detection for use with external mode locked lasers (e.g. Ti-sapphire)

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • Laser input optics for use with external mode-locked laser**
  • Motorized emission optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • R3809 MCP-PMT detector in cooled housing with close-coupled picotiming amplifier/discriminator
  • Fluoro3PS ultra-stable HV detector power supply
  • Emission monochromator: Seya-Namioka type, featuring motorized wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • FluoroHub timing electronics with FluoroHub-TE option for 0.7 ps/point resolution
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials) + DAS6-8 Anisotropy
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 37 x 70 cm baseplate
*Filters and polarizers are optional. For anisotropy measurements, FC-OP-LIO2 recommended for excitation channel and FC-OP-Pol1 or FC-OP-Pol2 for the emission channel.
**Laser not included
***System Installation is not included***

 

Back to Table
Back to Table

Protein 295ex
Lifetime system with 295 nm diode excitation, motorized optics and spectral capability

  • Large sample compartment (compatible with cryostats)
  • Cell holder with facility for recirculating liquid temperature control
  • Motorized excitation optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*: a wide choice of interchangeable laser diode and LED-based excitation sources are available as accessories
  • Motorised emission optics with 50 mm UV-grade fused silica lenses, filter holder for 50 mm square filters and mount for polarizer*
  • Emission monochromator: Seya-Namioka type, featuring motorised wavelength drive (200 nm to 800 nm), integral safety shutters interlocked to lid of sample compartment, and synchronized manually adjustable slits (1 nm to 32 nm)
  • NanoLED pulsed diode controller module (software controlled)
  • NanoLED-17 295 nm LED-based nanosecond pulsed excitation source
  • Bandpass filter for 295 nm excitation source
  • TBX-04 (185 - 650 nm) picosecond photon-detection module
  • FluoroHub timing electronics - measures picoseconds to seconds (depending on excitation source)
  • DataStation measurement software
  • DAS6 decay analysis software: Foundation Pack (including 1 to 5 exponentials) + DAS6-8 Anisotropy
  • Pentium D PC with Windows XP Professional and 17'' TFT monitor
  • All cables and interconnections
  • System supplied on a 37 x 70 cm baseplate
Recommended options
  • FC-OP-Pol2, Automatic Polarizers
  • FC-SC-05, 4-Cell Sample Turret
*Filters and polarizers are optional
***System Installation is not included***

 

Back to Table
Back to Table

UrAssay
LIF-based uranyl assay system

Back to Table

Click on the product for more detailed information
Speciality Systems
Lifetime System Protein 295ex
LIF-based System UrAssay

 

 

 

 

 

 

 

 

 

 Request Info














Request Info Request Info



  • Privacy Policy